スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
セッションID: C05
会議情報
C05 熱音響冷却システムの全長と形状が温度低下特性に与える影響について(パルス管冷凍機,熱音響機器及び関連要素と応用システム(2))
平野 宏之坂本 眞一塚根 芳将吉田 秀穂渡辺 好章
著者情報
会議録・要旨集 フリー

詳細
抄録
In this report we focus on the total length and the shape of the thermoacoustic cooling system called a loop-tube. It is confirmed that the fundamental resonance mode is desirable for high cooling effect. In addition, vertically long shape is better under the condition of the fundamental resonance mode. The cooling effect was evaluated by temperature decrease at the cooling point. Moreover the relation between the cooling effect and resonance mode was surveyed. From measurement result, loop-tubes resonated the fundamental resonance mode have higher cooling effect than others. Resonance mode relates to the viscous boundary layer formed in channels of stack. It is important that the viscous boundary layer in the case of the fundamental resonance mode keeps thinner than the channel radius of stack. And vertically long loop-tubes have high cooling effect. Under the condition of the same total length, vertically long shape is desirable for high cooling effect.
著者関連情報
© 2005 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top