熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: C146
会議情報
固体ディスプレーサ型熱音響発振器の性能評価 : ディスプレーサ重量の検討(オーガナイズドセッション3 蓄冷・蓄熱および熱輸送機器)
勝田 正文納富 信小野 和志寺村 朋晃田中 基之杉田 寛之
著者情報
会議録・要旨集 フリー

詳細
抄録
Because of employment of highly advanced earth observation sensors and employment of superconducting devices for communication equipment, number of missions with multi-cryocoolers tends to increase. Therefore, it is necessary to establish fundamental researches for space cryocooler development of small lightweight, high performance, high reliance, and a long-life. As the cooling system which responds to such a background, thermoacoustic devices attract attention. The attempt that uses a thermoacoustic engine for the pressure wave source of a pulse tube refrigerator is suggested, and if realized, application in space field is expected. In general, thermal compressors need a long resonance tube. Therefore, the system which operates solid displacer as resonator instead of a resonance tube was proposed. Though a great miniaturization of the device was achieved by adopting displacers, power loss in a displacer part became large, and a result which causes decline in efficiency was brought. Then, in this paper, the influence of displacer piston weight was investigated using three kinds pf displacers.
著者関連情報
© 2004 一般社団法人 日本機械学会