熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: E113
会議情報
E113 投影法ステレオストリークPTVを用いた3D3C時系列速度分布計測法の開発(OS-18: 熱・物質移動の計測および現象解析(1))
守矢 弦史椋木 伴紀菱田 公一
著者情報
会議録・要旨集 フリー

詳細
抄録
The internal blood flow of an aneurysm changes temporally and spatially according to the heartbeat and has a complex form; accordingly, time series volumetric velocity measurements are required. In the present study, we have developed a shadow imaged streak PTV system which enables time series volumetric velocity measurement with only two cameras. Applying this system to two types of aneurysm models in a cube measurement area, we have obtained three dimensional velocity streak results. The measuring volume size was 7.0 mm × 6.9 mm × 6.8 mm and velocity fluctuation was from 0.5 mm/s to 20.0 mm/s. Moreover, this system could accurately measure the small and large eddy changing spatially and temporally. From these results, it is concluded that the shadow imaged streak stereo PTV is applicable to milli-scale flows like an aneurysm.
著者関連情報
© 2012 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top