熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: J133
会議情報
J133 ゼオライトヒートポンプに用いるニードルフィン付熱交換器の性能の検討(一般講演(3))
加藤 泰生秋山 公介葛山 浩
著者情報
会議録・要旨集 フリー

詳細
抄録
Aiming at solution of the problem that the heat exchange speed of zeolite heat pump is slow, the time which 1 cycle takes is long, direct contact type particle packed bed's performance were examined focusing zeolite particle layer height. The findings by as a result making zeolite particle layer height high of there having been without time influence to saturation adsorption temperature, having more influence on the quantity of heat used for desorption per unit mass of the zeolite in a test section downstream site was acquired. As a result ,we found out that the direct contact heat exchanger had the advantage of making a particle layer thin.
著者関連情報
© 2012 一般社団法人 日本機械学会