日本口腔インプラント学会誌
Online ISSN : 2187-9117
Print ISSN : 0914-6695
ISSN-L : 0914-6695
原著
Ti-6Al-4V合金の線材から試験片を切り出す部位と疲労破壊および耐食性との関係
秋本 清河野 恭範日高 敏郎今村 直樹伊藤 聖輿 秀利梨本 正憲伊藤 充雄
著者情報
ジャーナル フリー

2017 年 30 巻 2 号 p. 94-101

詳細
抄録

This study examined the effects of changing the sampling sites of Ti-6Al-4V alloy manufactured by the wire drawing method on the hardness, elastic modulus, fatigue fracture, corrosion resistance, and observed structure of the alloy. The following results were obtained.
It was clarified that the hardness, elastic modulus, fatigue fracture, corrosion resistance, and structure of Ti-6Al-4V alloy manufactured by the wire drawing method were influenced by the sampling site. The test pieces parallel with the drawing direction were significantly inferior to those perpendicular to the drawing direction. It was thought that the extended α-phase in the drawing direction had an influence on this phenomenon. The material used to produce biomaterials should have uniformly excellent corrosion resistance and mechanical properties at all positions of the material.

著者関連情報
© 2017 公益社団法人日本口腔インプラント学会
前の記事 次の記事
feedback
Top