Journal of Veterinary Medical Science
Online ISSN : 1347-7439
Print ISSN : 0916-7250
ISSN-L : 0916-7250
NOTE
Effectiveness of Intraoperative Somatosensory Evoked Potential Monitoring During Cervical Spinal Operations on Animals with Spinal Cord Dysfunction
Seiichi OKUNOAmane NAKAMURATakayuki KOBAYASHIKensuke ORITO
著者情報
ジャーナル フリー

2005 年 67 巻 7 号 p. 719-722

詳細
抄録
We conducted somatosensory evoked potential (SEP) monitoring on 3 dogs with cervical spinal cord dysfunction caused by various diseases throughout operative procedures to examine whether the intraoperative SEP monitoring was effective for prediction of spinal cord conductive function. The SEP was recorded on the scalp via stimulation of the ulnar nerve. Stable SEP was recorded in all animals examined. Its amplitude was decreased by surgical manipulations of the regio vertebralis, but the amplitude gradually recovered once the manipulations were halted. The latency showed small variation throughout the operations. This evidence suggests that intraoperative SEP monitoring may provide continuous and instantaneous information regarding the functional integrity of the central nervous system.