Factors Influencing Measurement of Serum Iron Concentration in Dogs: Diurnal Variation and Hyperferritinemia
Seishiro CHIKAZAWAYasutomo HORIKazutaka KANAINaoyuki ITOFumio HOSHIKoichi ORINOKiyotaka WATANABESeiichi HIGUCHI
Author information
JOURNAL FREE ACCESS

2013 Volume 75 Issue 12 Pages 1615-1618

Details
Abstract

We evaluated diurnal variation and hyperferritinemia as factors that influence the values of serum iron concentration in dogs, using the International Committee for Standardization in Hematology (ICSH) colorimetric method. Serum iron levels were significantly higher in the morning than in the evening in 6 clinically healthy beagle dogs, and the maximum decrease in serum iron concentration was 47.3%. Moreover, the change in serum iron concentrations in 22 clinical canine cases with various serum ferritin levels was evaluated by immunoprecipitation of ferritin. The rate of decline in the serum iron concentrations positively correlated with serum ferritin levels (r=0.48, P=0.024). These results show that it is necessary to consider the sampling time and serum ferritin level for accurate interpretation of serum iron concentrations in dogs.