構造物に発生したき裂のK値測定用ゲージの開発
近藤 良之
著者情報
ジャーナル フリー

1987 年 53 巻 495 号 p. 1977-1982

詳細
抄録
The strain gage called "K-gage" was developed to measure the stress intensity factor (K) applied to a cracked member in structure. This gage measures the strain distribution around the crack tip and the measured strain is transformed into stress intensity factor. The accuracy of the measurement of the stress intensity factor is within ±10 percent compared to the exact value. Using this gage, the stress intensity factor can be measured directly under service conditions for an actual structure. It is expected to be a useful tool for the prediction of fatigue crack propagation life.
著者関連情報
© 社団法人日本機械学会