日本機械学会論文集 C編
Online ISSN : 1884-8354
Print ISSN : 0387-5024
地震時における加圧水型軽水炉の制御棒の挿入特性について
藤田 勝久篠原 義和南部 清仲戸川 哲人野村 友典
著者情報
ジャーナル フリー

1987 年 53 巻 487 号 p. 612-618

詳細
抄録
Control rod drop verification experiments of a pressurized water reactor under seismic conditions are performed to confirm the insertion function of control rods into a core. To evaluate these tests, computer simulations are performed. A fuel assembly, control rods, guide tube and other associated structures are immersed in a water tank, and shaken by four hydraulic shakers. The scram time of control rods under seismic conditions was measured, and confirmed to meet the scram function. Moreover, vibrational response characteristics of core structure and dropping behavior of control rods in consideration of collisions are calculated by using a finite difference method. The behavior of the dropping control rods and the scram time obtained by the computer simulation show a very good agreement with the verification experimental results.
著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top