Neurologia medico-chirurgica
Online ISSN : 1349-8029
Print ISSN : 0470-8105
ISSN-L : 0470-8105
Case Reports
Acute Angle-Closure Glaucoma After Successful Embolization of Traumatic Carotid-Cavernous Sinus Fistula
—Case Report—
Masaki KOMIYAMAToshie MORIKAWAYasuhiro MATSUSAKAToshihiro YASUIHisao SHIMIZU
著者情報
ジャーナル オープンアクセス

2003 年 43 巻 3 号 p. 142-145

詳細
抄録
A 69-year-old woman developed acute angle-closure glaucoma 2 weeks after successful transvenous coil embolization of a traumatic carotid-cavernous sinus fistula. The angle-closure glaucoma was precipitated by oculomotor palsy caused by transvenous coil packing of the cavernous sinus. Emergency iridotomy resulted in normalization of the intraocular pressure and restoration of vision. Acute angle-closure glaucoma may develop in association with an oculomotor palsy caused by any etiology, including neurointervention.
著者関連情報
© 2003 by The Japan Neurosurgical Society

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback
Top