精密工学会学術講演会講演論文集
2018年度精密工学会春季大会
会議情報

Characteristics Investigation of ECM with Electrolyte Suction Tool with Built-in Auxiliary Anode for Narrowing Current Area
*Liu Guixian日極 さおり夏 恒
著者情報
会議録・要旨集 フリー

p. 911-912

詳細
抄録

The suction tool was applied to the electrochemical machining due to the characteristics of its restrained electrolyte flow. In this paper, a new suction tool with built-in auxiliary anode is designed and applied to electrochemical machining. Since the function of the built-in auxiliary anode is to further constrain the electric field and lead to a narrower current area in the inter-electrode gap in addition to the constrained electrolyte flow, higher machining precision can be achieved. Based on the tool structure, the numerical simulation of electric field is carried out to show the effectiveness of the new tool. The machining characteristics of the new tool are also experimentally investigated.

著者関連情報
© 2018 公益社団法人 精密工学会
前の記事 次の記事
feedback
Top