D-20 戸建住宅を対象とした通風性能評価手法に関する研究 : その5 シェルター性能を変化させた場合の通風性能に関する研究
赤林 伸一坂口 淳
著者情報
会議録・要旨集 フリー

詳細
抄録
In this study, cross ventilation efficiency for the detached house was evaluated by the multi zone network airflow simulation and the CFD. This study was analyzed about the relationship between a shelter performance of the detached house and CVDHIT and cooling load. The results are as follows: (1) As insulation performance becomes higher, CVDHIT and the cooling load reduction rate is higher, the annual cooling load is lower, and ventilation performance is higher. (2) CVDHIT and the annual cooling load is lower by blocking direct solar radiation on the window. (3) CVDHIT and the annual cooling load is lower by the eaves on the window.
著者関連情報
© 2009 公益社団法人 空気調和・衛生工学会