計測自動制御学会論文集
Online ISSN : 1883-8189
Print ISSN : 0453-4654
ISSN-L : 0453-4654
論文
体幹設置型遠隔診断エコーデバイスにおける人体装着機構に応じた装着容易性と安定性の比較評価
朝山 智史伊藤 慶一郎鶴田 功一菅野 重樹中村 京太岩田 浩康
著者情報
ジャーナル フリー

2013 年 49 巻 1 号 p. 86-92

詳細
抄録
It is necessary for the patient who met with a traffic accident to perform echography immediately. We have developed the tele-echography device which the doctor who is in the hospital during transportation can inspect by remote control. In this paper, we report new attachment mechanisms of the device. Conventional system has an attachment mechanism with a corset. This mechanism has to pass a corset through between patient's body and ground. It is hard to attach this device to patient used by this method. Furthermore patient suffers damage by moving their body. We developed, therefore, new mechanisms which we can put it on the front of the body and evaluated their installability and robustness in a vehicle.