バイオメカニズム学会誌
Print ISSN : 0285-0885
ショートペーパー
目視検査における検査時間が欠点検出率に及ぼす影響に関する研究
志田 敬介中嶋 良介康 秀徳
著者情報
ジャーナル フリー

2013 年 37 巻 2 号 p. 134-138

詳細
抄録
In order to consider visual inspection utilizing peripheral vision, this paper examines the inspection times that affect defect detection. The gaze duration and the distance between defect and point of gaze are experimental factors in determining the inspection time. As the result, in case of a large sized defect, the detection rate is high regardless of the gaze duration and the distance between defect and point of gaze. In case of a small sized defect, when the gaze duration is longer and the distance between defect and point of gaze is closer, the defect detection rate is higher. Moreover, as the result of conducting multiple linear regression analysis about the experiment factors, it is obtained that judging from standardized partial regression coefficient of factors, higher defect size, less the distance between defect and point of gaze, higher gaze duration, is proved to improve defect detection.