グローブボックスパネル材の熱分解特性に対するガンマ線照射の影響の検討
阿部 仁, 渡邊 浩二, 内山 軍蔵
著者情報
ジャーナル フリー

2014 年 13 巻 4 号 p. 136-144

詳細
抄録
  The glove box (GB) is a device with some plastic components and is used for the containment of radioactive materials. In a MOX fuel fabrication facility, MOX is also handled in the GB. Since the plastic panel, which has the largest area in the GB, is used over a long period, it is exposed to a high dose of MOX continuously. In this study, to confirm whether the containment capability of GB can be maintained even under external thermal stress, the effects of gamma ray irradiation with 60Co on the pyrolysis properties of the common panel materials were investigated by TG-DTA. As a result, polymethylmethacrylate showed a large peak of the mass loss rate at about 260 degrees under the nonirradiation and air condition, but it separated into lower and higher temperature sides above 25 kGy. This effect was not observed up to 10 kGy for polymethylmethacrylate and up to 880 kGy for polycarbonate. By comparison with the estimated total dose of the GB panel irradiated in the operation period, it was found that the irradiation from MOX does not significantly affect the pyrolysis properties of the GB panel in the actual facility.
著者関連情報
© 2014 一般社団法人 日本原子力学会