含フッ素ジアルキルエーテルの液体密度
中沢 宜明佐古 猛中根 堯関屋 章河村 光隆佐藤 眞士望月 雄司高田 直門安本 昌彦
著者情報
ジャーナル フリー

1997 年 14 巻 2 号 p. 105-112

詳細
抄録
The liquid densities of thirteen fluorinated ethers which are expected as promising candidates of CFC alternatives were measured at temperatures from 278 K to 323 K and atmospheric pressure. The fluorinated ethers used in this study are 1-difluoromethoxy-1,1, 2- trifluoroethane, 1-methoxy-1, 1,2,2-tetrafluoroethane, 1-methoxy-2,2 ,3 ,3- tetrafluoropropane, 1-methoxy-1-trifluoromethy1-2,2 ,2- trifluoroethane, 1-methoxy-1,1,2,2, 3-hexafluoropropane,1-difluoromethoxy-2,2, 3, 3 -tetrafluoropropane, 1-methoxy-heptafluoropropane,1-difluoromethoxy-2, 2, 3, 3, 3-pentafluoropropane, 1- (2, 2, 2-trifruoroethoxy) -1, 1, 2,2-tetrafluoroethane, 1-pentafluoroethoxy-1, 1, 2, 2-tetrafluoroethane,2-trifluoromethoxy-1, 1, 1,2-tetrafluorobutane, 1-proxynonafluorobutane, and 1-ethoxy-undecafluoropentane.
The liquid density has been measured by the vibrating tube densitometer (ANTON PARR, DMA 602) within an error of 0.07%.
The liquid densities decrease monotonically with increase of temperature.
著者関連情報