日本冷凍空調学会論文集
Online ISSN : 2185-789X
Print ISSN : 1344-4905
ISSN-L : 1344-4905
論文
Measurement of Isobaric Heat Capacity of Gaseous Trans-1,3,3,3-tetrafluoropropene (HFO 1234ze (E) )
Noboru KAGAWAAtsushi MATSUGUCHIKoichi WATANABE
著者情報
ジャーナル フリー

2011 年 28 巻 1 号 p. 71-76

詳細
抄録
The specific isobaric heat capacity (cp) was measured for HFO-1234ze(E) (trans-1,3,3,3-tetrafluoropropene) in the gas phase. HFO-1234ze(E) has a lower GWP value of 6 and is one of new environment-friendly refrigerants. Nineteen measurements for HFO-1234ze(E) were obtained at temperatures from 303 K to 363 K and at pressures from 0.35 MPa to 1.3 MPa. The expanded uncertainty (k=2) of the temperature measurements is estimated to be less 22 mK, and that of the pressure measurements is less 4.4 kPa. The expanded uncertainty for cp is estimated to range from 14 to 21 J.kg-1.K-1.
著者関連情報
© 2011 Japan Society of Refrigerating and Air Conditioning Engineers
前の記事 次の記事
feedback