日本冷凍空調学会論文集
Online ISSN : 2185-789X
Print ISSN : 1344-4905
ISSN-L : 1344-4905
論文
デシカントハイブリッドヒートポンプの冬季ノンフロスト運転性能評価
古谷野 赳弘中川 直紀党 超鋲飛原 英治神戸 正純綾目 久雄黒田 尚紀
著者情報
ジャーナル フリー

2014 年 31 巻 2 号 p. 79-90

詳細
抄録
This paper proposes a desiccant hybrid heat pump for enabling frost-free operation of heat pumps in humid regions in winter.Experimental measurements using mesoporous silica, which can operate at low temperatures, validated that removal of water vapor from the incoming air of the evaporator was effective in preventing the formation of frost. The results also confirmed that this system provides higher efficiency if the absorbed water can be used for humidification. Based on the experimental results, a theoretical model was constructed and results of a simulation using this model showed that the proposed system could meet the humidity requirement in a relatively wide range (0.5-1) of the sensible heat factor.