昇温型吸収ヒートポンプによる高性能乾燥システム
第2報 動的性能とその熱的評価
西村 伸也野邑 奉弘藪下 明弘柏木 孝夫
著者情報
ジャーナル フリー

1990 年 7 巻 3 号 p. 265-274

詳細
抄録
A computer simulation has been developed on transient drying process in order to predict the dynamic thermal performance of a new superheated steam drying system using an absorption type temperature amplifier as a steam superheater. A feature of this drying system is that one can reuse the exhausted superheated stream conventionally discharged from the dryer as a driving heat source for the generator in this heat pump. But in the transient drying process, the evaporation of moisture sharply decreases. Accordingly, it is hardly expected to reuse an exhausted superheated steam as heating source for the generator. 80 the effects of this exhausted superheated steam and of changes in hot water and the cooling water temperatures were mainly investigated checking whether this drying system can be driven directly by the low level energy of sun or waste heat. Furthermore, the system performances of this drying system were evaluated on a qualitative-basis by using the exergy efficiency. The results show that, under the transient drying conditions, the temperature boost of superheated steam is possible at a high temperature and thus the absorption type temperature amplifier can be an effective steam superheater system.
著者関連情報
© 1990 公益社団法人 日本冷凍空調学会