IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524
Special Section on Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2007)
The Relationship between Voltage and Duration of Short-Time Arc Generated by Slowly Breaking Silver Contact
Yoshiki KAYANOHikaru MIURAKazuaki MIYANAGAHiroshi INOUE
著者情報
ジャーナル 認証あり

2008 年 E91.C 巻 8 号 p. 1230-1232

詳細
抄録
Arc discharge generated by breaking electrical contact is considered as a main source of an undesired electromagnetic (EM) noise. To clarify mechanism of generation of the EM noise, feature extraction of bridge and short-time arc waveforms generated by slowly breaking Ag contact was discussed experimentally. The short-duration time arc before the ignition of the continuous metallic arc discharge was observed. The highest probability density voltage is defined as short-arc sustainable voltage (SASV). The relationship between SASV and duration of short-time arc was quantified experimentally. It is revealed that as the arc voltage of the short-time arc is higher, its duration becomes longer.
著者関連情報
© 2008 The Institute of Electronics, Information and Communication Engineers
前の記事 次の記事
feedback
Top