IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524

This article has now been updated. Please use the final version.

Measuring SET Pulse Widths in pMOSFETs and nMOSFETs Separately by Heavy-ion and Neutron Irradiation
Jun FURUTAShotaro SUGITANIRyuichi NAKAJIMATakafumi ITOKazutoshi KOBAYASHI
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 2023ECP5045

Details
Abstract

Radiation-induced temporal errors become a significant issue for circuit reliability. We measured the pulse widths of radiation-induced single event transients (SETs) from pMOSFETs and nMOSFETs separately. Test results show that heavy-ion induced SET rates of nMOSFETs were twice as high as those of pMOSFETs and that neutron-induced SETs occurred only in nMOSFETs. It was confirmed that the SET distribution from inverter chains can be estimated using the SET distribution from pMOSFETs and nMOSFETs by considering the difference in load capacitance of the measurement circuits.

Content from these authors