In recent years, sudden and a large quantity of rainwater in the urban area flows into the drainage pumping station by the
expansion of the drainage district by the city area promotion, the decrease of the basement osmosis area by the pavement
rate improvement, the squall die rain by the heat island effect, and the problem that submergence damage occurs by a starting
delay of the rainwater drainage pump. In order to prevent such submergence damages, what is called as full speed standby
pump system makes carry out idling reserve operation of the pump in preparation for a flood, and it enables to drain
immediately at a flood condition are adopted, and the pump system is introduced into the drainage pumping station.
However, since usually bigger excitation force than in usual operation of single phase occurs in gas-liquid two phase operation.
In the present paper, the excitation force in gas-liquid two phase operation in a vertical volute pump is investigated.
The changed of excitation force and the causes of its increasing with experimental data. Finally the important matter in actual
designing is summarized.