  • 中村 和人
    電気学会論文誌E(センサ・マイクロマシン部門誌)
    1997年 117 巻 1 号 15-19
    発行日: 1996/12/20
    公開日: 2009/04/01
    ジャーナル フリー
    A precise drilling technology with cross section control for use on thin ceramic materials has been developed using Excimer laser photo-ablation process. An homogenous illumination optical system and projection system of high resolution optical elements are applied to a newly designed mass production system. Homogeneity of laser energy under±5% on the mask surface has been obtained by the illumination system, making a final hole array with a distribution of exit hole diameter of 3.5±0.7μm in one processing field of 1.2×1.2mm square area. If a crack occurs in the process because of high repetition rate or high energy from the laser, productivity declines. Designing a specimen holder and He-gas assist enabled cracks to be avolded even at high repetition rate of 200Hz.
    This paper describes hole array drilling technique with cross section control of ceramics by multi musk method, production system and an application.
  • 矢部 明
    電気学会誌
    1995年 115 巻 6 号 352-355
    発行日: 1995/05/20
    公開日: 2008/04/17
    ジャーナル フリー
  • 田辺 郁子, 畑崎 泰定, 高橋 千秋, 阿曽沼 早苗, 大杉 有加, 上嶋 恵, 不二門 尚, 高橋 圭三, 大橋 裕一, 木下 茂
    日本視能訓練士協会誌
    1993年 21 巻 65-68
    発行日: 1993/12/31
    公開日: 2009/10/29
    ジャーナル フリー
    年齢25~70歳で術前の不同視の程度が4.1D~7.1Dの,近視性不同視の症例4例4眼に
    エキシマ
    レーザーによるPRK(photorefractive keratectomy)を施行し,術後の視機能を検討した.屈折は,術後6ヵ月時で平均4.3D遠視化し,狙いの矯正度数に対する達成率は平均109%で,不同視の程度は,平均5.8Dから1.5Dに改善した.視力は,矯正視力は殆ど変化なかったが,裸眼視力は大幅に改善した.コントラスト感度は,角膜上皮下混濁がピークの術後1~3ヵ月には術前のレベルより低下するが,角膜上皮下混濁がほぼ消失する術後6ヵ月には術前のレベルに回復した.コントラスト感度が低下しても,矯正視力は低下しなかった.
    エキシマ
    レーザーによるPRKは,不同視の改善に有用であり,今後が期待されると思われるが,臨床導入の前に視機能への影響を十分に検討していく必要があると思われる.
  • 佐藤 勝彦, 藤坂 紳一
    電気学会論文誌C(電子・情報・システム部門誌)
    1994年 114 巻 5 号 529-534
    発行日: 1994/05/20
    公開日: 2008/12/19
    ジャーナル フリー
  • 加藤 治文, 岩淵 裕, 山本 秀樹, 奧仲 哲弥, 池田 徳彦, 玉地 義弘, 会沢 勝夫
    日本レーザー医学会誌
    1987年 8 巻 3 号 167-168
    発行日: 1987年
    公開日: 2012/09/24
    ジャーナル フリー
    Newly developed excimer dye laser system for cancer diagnosis and treatment was evaluated clinically. Diagnosis and treatment were performed photodynamically after the administration of HpD. Five patients with lung cancer consisting of four cases of squamous cell carcinoma and a single case of adenocarcinoma showed HpD-specific fluorescenc at the lesions. In the treatment, 50-140 joules/cm2 photoradiation were administered to the lesions. All lesions showed significant remission. A case of early stage squamous cell carcinoma of the right upper lobe bronchus showed complete remission and is now disease free at 11 months. This system is more effective in the diagnosis and treatment than previous procedures.
  • 早田 義博, 加藤 治文, 野口 正之, 中鳴 伸
    BME
    1987年 1 巻 7 号 532-535
    発行日: 1987/07/10
    公開日: 2011/09/21
    ジャーナル フリー
    パルスレーザーであり, 尖頭出力の高い
    エキシマ
    ダイレーザーを用いた癌の診断装置が開発されつつある. 従来の装置に比較し, 診断面では, より確かな局在診断が, 治療面では, より深部への治療効果が期待される. 肺癌症例でその効果が確認された.
  • 阿部 裕輔, 今西 薫, 祖川 伊知朗, 野垣 健一, 米沢 卓実, 鎮西 恒雄, 鈴川 正之, 丹羽 真一郎, 四谷 幸朗, 満渕 邦彦, 井街 宏, 田子 友太郎, 河野 明正, 小野 俊哉, 渥美 和彦, 藤正 巌
    日本レーザー医学会誌
    1990年 11 巻 Supplement 号 297-300
    発行日: 1990年
    公開日: 2012/09/24
    ジャーナル フリー
    We have been studied to establish the requirement for the coronary laser endoscope with animal experiment using goats' coronary arteries by developing various coronary laser endoscopes. The purpose of this study was to develop coronary laser endoscope in which the tip had the bending function.
    In this study, the laser endoscope with the diameter of 1.7mm which is thought to be applicable to the coronary artery, in which the tip had two directional bending function, was developed. The endoscope was evaluated with goat's carotid artery which was partially occluded with organized thrombus made by the interposition of Gore-Tex artificial graft.
    The endoscopic view was very improved with two directional bending function of the tip, and excimer laser could be scanned in line to destruct the thrombus.
    More than three directional bending function of the tip is required to improve the scanning ability of laser and is the most important next subject.
  • 補助循環を用いた心拍動停止下手術の可能性
    阿部 裕輔, 今西 薫, 米沢 卓実, 鎮西 恒雄, 祖川 伊知郎, 四谷 幸朗, 野垣 健, 井街 宏, 満渕 邦彦, 河野 明正, 小野 俊哉, 田子 友太郎, 丹羽 真一郎, 渥美 和彦, 藤正 巖
    日本レーザー医学会誌
    1992年 13 巻 Supplement 号 507-510
    発行日: 1992年
    公開日: 2012/09/24
    ジャーナル フリー
    The research for the endoscopic coronary laser angioplasty system using excimer laser and a very thin diameter endoscope has been performed since 1987 by us. To date, the laser endoscopic system, which is able to approach into the coronary artery percutaneously, could be developed. However in-vivo study showed that there remained the following problems; 1) it was impossible to make the laser aiming under the moving visual field caused by the beating of the heart, 2) it was impossible to perform the operation successfully within a few minutes of manipulation inside coronary because of the ischemie of the heart.
    In order to improve these problems, we tried to examine the possibility of the procedure in the arrested heart by using the circulatory assistance.
    The PCPS system was used for the circulatory assistance. The endoscopic coronary laser angioplasty system consist of the long-pulse excimer laser (308nm wave length, 8Ons pulse duration) and the ultra-thin laser endoscope (1.5mm diameter) for the coronary artery was used for the experiment. The endoscope had the 4-directional bending function at the tip.
    Four goats with about 50kg weight were used. When the heart was beating, it was impossible to aim the target with the laser. However, when the heart was arrested under the circulatory assistance, the target could be aimed successfully with laser. The arrested heart was begun to beat again with the DC shock after the examination. In the experiment of the endoscopic coronary laser angioplasty, the heart was arrested immediately after the insertion of the skin tissue into the coronary artery by the acute myocardial infarction. Under the circulatory assistance, the excimer laser did not failed to be aimed to destroy the obstruction. However, the length of the obstruction was too long to remove the obstruction completely. The safety and reliable endoscopic coronary laser angioplasty would be possible, if the safety cardiac arrest condition was obtained in future.
  • 住 洋夫, 後久 真輝, 行村 建
    電気学会論文誌A(基礎・材料・共通部門誌)
    1997年 117 巻 4 号 419-425
    発行日: 1997/03/20
    公開日: 2008/07/15
    ジャーナル フリー
    Electrical characteristics of a silent discharge for a rare-gas excimer excitation for 5 to 10kV of applied voltage with 3 to 15kHz of source frequency are discussed. It is found that there is a similarity relation between a consumed power at the gap and product of frequency and specific applied voltage. A number of spike discharge increases by increasing an applied voltage, while the light intensity of a spike discharge maintain constant. It is inferred from the measured power that pumping power is approximately about 400kW/cm3 and a reduced electric field strength is about 25Td. From a high reduced electric field, an effective excitation of raregas excimer may be obtained.
  • 皮膚照射後の短期観察
    村井 睦彦, 落合 聡, 橋本 賢二, 山田 一郎, 山本 肇, 佐藤 勝彦
    日本レーザー歯学会誌
    1992年 3 巻 1 号 51-56
    発行日: 1992/06/01
    公開日: 2010/10/21
    ジャーナル フリー
    The purpose of this study was to investigate the short-term biological effects of Excimer Laser. The surface of the skin in the rat was irradiated with KrF Excimer Laser at wave length of 248nm for 30 seconds at pulse repetition rate of 10Hz and pulse width of 15nsec.
    Energy density was 3.1mJ/cm2, 47.6mJ/cm2, 160.0mJ/cm2, 576.9mJ/cm2 or 1714.2mJ/cm2.The irradiated skin tissue was removed of various times between 1 hour and seven days after rradiation and with H-E stain for pathological examination. Necrosis was observed in epidermis irradiated at 47.6mJ/cm2 and in dermis irradiated at 576.9mJ/cm2, and defect of the muscular tunic was observed in tissue irradiated at 1714. 2mJ/cm2. These results indicate that depth of skin defect is related to energy density and that necrosis occurs at energy density ranging from 3.1mJ/cm2 to 47.6mJ/cm2. Satisfactory wound was observed after irradiation at each energy density.
  • 小池 英仁, 行村 建
    電気学会論文誌A(基礎・材料・共通部門誌)
    1998年 118 巻 1 号 65-70
    発行日: 1998/12/20
    公開日: 2008/07/15
    ジャーナル フリー
    An arc generation of a long-pulse spiker-sustainer excimer laser with about 250ns of pulse width, is discussed by using time-varying spectroscopic method. First arcing occurs during a main discharge for laser excitation and shows XeII spectrum, while a glow-like discharge represents only XeI spectrum, the metallic spectrum such as NiI caused by vaporization of electrode material begins to appear just after the termination of the main discharge. Second arcing occurs after about 2μs, which brings strong intensity of NiI spectrum. It means that the reignition arc might be produced in a metallic vapor that appears during the main discharge. Accordingly, it is concluded that the reignition arc is inherently metallic, which is different from the main arc with rare gas plasma.
  • ロンゲパルスヱキシマレーザーのファイバー導光と動脈硬化組織における作用
    祖川 伊知郎, 阿部 裕輔, 今西 薫, 米沢 卓実, 鎮西 恒雄, 丹羽 真一郎, 四谷 幸朗, 野垣 健, 満渕 邦彦, 井街 宏, 渥美 和彦, 藤正 巌
    日本レーザー医学会誌
    1991年 12 巻 Supplement 号 348-351
    発行日: 1991年
    公開日: 2012/09/24
    ジャーナル フリー
    Experimental results of fiberoptical delivery and a reaction on atherosclerotic tissue using a long pulse excimer laser are described. In order to improve the maximum energy delivered through optical fiber, a long pulse excimer laser which had the pulse duration of 100nsec was examined. The quartz fibers with both 300 and 400μm core diameter were used for the laser energy delivery. As a result, the maximum energies transmitted through optical fiber were 30mJ/pulse with 400μm core fiber and 16mJ/pulse with 300μm core fiber. And the average energies transmitted constantly were 20mJ/pulse and 10mJ/pulse with 400μm core fiber and 300μm core fiber, respectively. The energies were about 3 times lager than these using a conventional short pulse excimer laser. The laser energy delivered through the fiber was irradiated on the sample of atherosclerotic aorta of a rabbit in saline to investigate the tissue reaction on atheroma. The result shows that the fiberoptically delivered energy of long pulse excimer laser was enough for the destruction of atherosclerotic tissue.
  • 阿部 裕輔, 今西 薫, 米沢 卓実, 鎮西 恒雄, 鈴川 正之, 丹羽 真一郎, 四谷 幸朗, 祖川 伊知朗, 上宮 崇文, 金沢 進一, 野垣 健, 満渕 邦彦, 井街 宏, 田子 友太郎, 河野 明正, 小野 俊哉, 渥美 和彦, 藤正 巌
    日本レーザー医学会誌
    1989年 10 巻 3 号 117-120
    発行日: 1989年
    公開日: 2012/09/24
    ジャーナル フリー
    We have been developing coronary laser angioplasty system with excimer laser. And the coronary laser endoscopic system has been developed to realize visual coronary laser angioplasty.
    In order to design the coronary laser endoscopic system, various kinds of endoscope were developed experimentally and evaluated with animal experiment using goat to establish the requirement for the coronary laser endoscope.
    The requirement for coronary laser endoscope was clarified to be as follows:
    1, Diameter: 1.5-1.8mm max (goat, 50kg)
    2, Flexibility of the tip: flexibility is required and the combination of guide wire is useful for the successful coronary approach with endoscope.
    3, Stiffness of the body: stiffness is required for the better handling.
    4, Image fiber: 2000 pixel is possible. Light guide: good
    5, Bending function of the tip: 4 direction (at least 1 direction)
    6, Cannel: 1 channel for the guide wire and laser fiber passage.
    In present time, the bending function of the tip to 4 direction is not developed yet, and the technique of bending mechanism is being studied.
  • 井岡 浩匡, 稗田 牧, 中村 葉, 木下 茂
    視覚の科学
    2015年 36 巻 2 号 25-30
    発行日: 2015年
    公開日: 2015/09/11
    ジャーナル フリー
    目的:Photorefractive keratectomy(PRK)術後15 年以上の長期経過観察が可能であった症例に対し,角膜形状解析装置により角膜前面屈折力の変化について検討し,PRK の術後角膜形状の安定性について評価した。  方法:対象は,PRK を実施し15 年以上経過観察が可能であった7 例12 眼として,角膜形状解析を行った。測定は角膜形状解析装置TMS にて実施し,検討項目はsimulated keratometry(SimK),differential map(DM),surface regularityindex(SRI),surface asymmetry index(SAI),corneal eccentricity index(CEI)の5 項目とした。各項目を,術前,手術施行から0.5,1,5,10,15 年目時点で測定している角膜形状データから各検討項目を抽出し評価した。  結果:SimK では術後1 年と比べ,その後15 年までsteep 傾向への緩やかだが有意な変化がみられた(p<0.05)。DM では,術後1 年以内の変化量と5 年目以降の変化量を比較,5 年目以降の変化は有意に少なくなっていた(p<0.05)。SRI・SAI では術後1 年まで変動し不安定であるが,術後1 年以降は術後15 年まで安定を示した。CEI では手術により角膜形状はoblate を示したが,それ以降術後15 年まで,わずかずつプラス方向への変化がみられるが有意差はなかった。  結論:術後早期では変動があるものの1 年以降は安定的であり,5 年目以降の変化は非常に軽微な変化であった。このわずかな変化では角膜中央部はsteep,角膜全体はprolate 傾向の変化を示した。不正乱視の15 年間の変化は正常範囲であり,PRK 術後においても安定的であった。
  • 和田 麻衣子, 里村 暁子, 伊東 孝通, 高原 正和, 古江 増隆
    西日本皮膚科
    2014年 76 巻 5 号 459-464
    発行日: 2014/10/01
    公開日: 2015/02/03
    ジャーナル 認証あり
    14 歳,女児。2008 年 4 月中旬より頭頂部・頭部左側の脱毛に気付き,塩化カルプロニウム・ステロイドの外用,セファランチン・グリチルリチン酸の内服を開始するも改善を認めなかった。同年 11 月上旬よりスクアレン酸ジブチルエステル (SADBE) による局所免疫療法を開始したが,2010 年 5 月頃より徐々に脱毛巣が拡大し,同年 8 月頃より蛇行状脱毛症の像を呈した。本人・両親の同意を得て,2011 年 4 月下旬より
    エキシマ
    ライト療法を開始した。照射開始前は頭部左側から後頚部にかけて,生え際に帯状の脱毛を認めた。脱毛面積は 25%以上 49%未満で「日本皮膚科学会円形脱毛症診療ガイドライン 2010」1) の分類上,S2 であった。150 mJ/cm2 から照射を開始したところ照射開始 1 カ月後頃から少しずつ発毛を認め,照射開始 3 カ月後で 75%以上の発毛を認めた。小児の円形脱毛症に対しても
    エキシマ
    ライト療法が有効な症例があると考えられる。
  • 阿部 裕輔
    日本レーザー医学会誌
    1991年 12 巻 Supplement 号 371-374
    発行日: 1991年
    公開日: 2012/09/24
    ジャーナル フリー
    The endoscopic coronary laser angioplasty system using excimer laser thin diameter endoscope has been developing.
    In order to improve the transmitted energy through the laser fiber, long pulse excimer laser was used for the experiment. This laser could oscillate 308nm wavelength (XeCl) with maximum I 50m.1 per pulse energy and 100ns pulse duration.
    In order to improve the bending function at the tip of the endoscope. the endoscope, which had 4 directional bending function at the tip and had one channel for the laser fiber, was developed and evaluated using organized thrombus inside the goat's carotid artery which was made beforehand by the interposition of artificial graft with I cm length.
    Using this long pulse excimer laser, the transmitted laser energy was improved to be maximum 30mJ/pulse and average 15mJ/pulse using the optical fiber for ultra violet laser transmission with 400μm core diameter. The energy was enough to destruct the atheroma with non-contact irradiation.
    The developed endoscope had 1.5mm diameter, 1.7mm diameter at the tip and 150cm inserting length. Th endoscope had 4 directional bending function with 10-20° for each direction. The laser could be scanned to organized thrombus to destructed through this endoscope. This endoscope improved the scanning ability of laser irradiation. As the endoscope had small diameter enough to attach the coronary artery, it is possible to perform the experiment with coronary artery for the next step.
  • 第4報摘出ヒト下顎骨骨切りと切開部所見
    磯部 誠, 吉田 憲司, 石田 悟, 深谷 昌彦, 佐藤 勝彦
    日本レーザー歯学会誌
    1995年 6 巻 1 号 25-30
    発行日: 1995/06/01
    公開日: 2010/10/21
    ジャーナル フリー
    The KrF excimer laser is a high power pulsed laser oscillating in the ultraviolet field and able to destroy or amputate molecules of tissue without thermal damage.
    In order to evaluate the effects of KrF excimer laser irradiation on human mandibular bone, we examined by visual, pathological and SEM observation.
    The laser irradiation on human mandibular bone resected by oral and maxillofacial surgery had a pulse energy: 65mJ, spot size: 0.80×0.50mm2, energy density: 16J/cm2, water volume: 6.5ml, assist gas (N2): 301/min, frequency: 80Hz, incision speed: 5, 10, 15mm/min.
    Visual observation: the incisions were sharp without thermal damage, and the depth of the inicions ranged from 0.68 to 2.53mm according to the incision speed.
    Pathological observation: the inicisions were almost sharp and there was almost no thermal damage layer.
    SEM observation: the incision section was slightly wavy, but the incision surface was almost clear at 20 magnification. Crystals formed at the incision surface at all incision speeds, and there was no melting of bone tissue at 5000 magnification.
  • -第3報ブタ下顎骨切開時の注水の影響-
    磯部 誠, 松下 秀典, 吉田 憲司, 深谷 昌彦, 佐藤 勝彦
    日本レーザー歯学会誌
    1993年 4 巻 1 号 45-48
    発行日: 1993/06/01
    公開日: 2010/10/21
    ジャーナル フリー
    Recently, lasers operating at shorter and shorter wavelengths have becomeavailable. The excimer laser emits pulses of ultraviolet wavelengths.The KrF excimer laserhas high incision efficiency, and can cut hard tissue without thermal damage. An incisionwas made on the mandibular bone of a pig by laser under the following conditions. Frequency: 60Hz, pulse energy: 32mJ, pulse width: 15ns, beam spot size: 1.5×0.4mm2, energy density: 5.3J/cm2, irradiation time: 5min, volume of distilled water: 5l/min, andvolume of assist gas: 30l/min. After irradiation, visual, pathological and SEM observations was carried out. There were almost no thermal damage layers. The surface of boneincision was comparatively sharp. But, SEM finding showed the melting of tissue at the surface of bone.
  • 平野 達, 鈴木 健司
    日本レーザー医学会誌
    1995年 16 巻 1 号 29-35
    発行日: 1995年
    公開日: 2012/09/24
    ジャーナル フリー
    光増感剤PHEと
    エキシマ
    ダイレーザー (EDL) の組合せにより, 光線力学的治療法 (PDT) が早期の肺癌 (0期及び1期), 食道癌, 胃癌, 子宮頚及び異形成に対して承認された。本文では医療用具として認められたEDLの構成, レーザー光の照射プローブ, 治療用のコルポスコープについて説明した。臨床試験 (治験) では, 0期肺癌, 食道癌, 胃癌, 子宮頚癌及び異形成でほぼ良好な治療成績が得られたが, 1期肺癌と膀胱癌では成績は良くなかった。この原因として照射光量の不足が考えられた。EDLにより組織の深く迄効果が及ぶことは明かと思われるが, この理由について推察した。
  • 南谷 靖史, 斉藤 善夫, 佐藤 行雄
    電気学会論文誌A(基礎・材料・共通部門誌)
    1997年 117 巻 7 号 779-780
    発行日: 1997/06/20
    公開日: 2008/07/15
    ジャーナル フリー