航空宇宙技術
Online ISSN : 1884-0477
ISSN-L : 1884-0477
小型ループヒートパイプのリザーバ制御による動作特性の向上
福吉 芙由子長野 方星小川 博之永井 大樹
著者情報
ジャーナル フリー

2010 年 9 巻 p. 49-55

詳細
抄録
This paper reports test results of active control of heat transfer performance of a small loop heat pipe (LHP) with a thermoelectric converter (TEC) in an atmospheric condition. The TEC is attached to a reservoir of the LHP to control the operating temperature by heating and cooling using a bipolar power supply. Tests were conducted by varying the evaporator power, the reservoir set point temperature, and the condenser sink temperature. The test results showed that the TEC is able to control the LHP operating with small electric power. The test results also demonstrated enhancement of the start-up success by maintaining a constant reservoir temperature during the start-up process. Forced shut-off of the loop operation by rapid heating of the reservoir was also demonstrated.
著者関連情報
© 2010 The Japan Society for Aeronautical and Space Sciences
前の記事 次の記事
feedback
Top