Biological and Pharmaceutical Bulletin
Online ISSN : 1347-5215
Print ISSN : 0918-6158
ISSN-L : 0918-6158
Separation and Determination of Phospholipids in Plasma Employing Thin-Layer Chromatographic Plate with Concentration Zone or Solid Phase Extraction
鈴木 恵美佐野 昭光栗木 武男三木 太平
著者情報
ジャーナル フリー

1993 年 16 巻 1 号 p. 77-80

詳細
抄録

Two efficient extraction methods for phospholipids have been established employing a TLC plate with a concentration zone or a solid-phase extraction cartridge. First, small amounts of five authentic phospholipids, 10 to 100μg each, were separated on a TLC plate with a concentration zone. These phospholipids were not adsorbed to the silica gel of this TLC plate and the substrates were recovered in good yields. Second, a solid-phase extraction cartridge containing NH2-modified silica gel was able to retain all of the authentic phospholipids among C18-, diol-, and CN-modified silica gel and silica gel beds. Elution of neutral and acidic phospholipids from the NH2-cartridge was carried out with a chloroform-methanol mixture and a chloroform-methanol-28% ammonium mixture containing 0.05M ammonium acetate, respectively.Recovery tests on the above two methods were carried out by conventional capillary gas chromatography. Thus, not less than 95% of each phospholipid was recovered from the TLC plate or NH2-cartridge in a 10 to 100μg sample range. Also, the standard deviation of repeatability of recovery for phosphatidylcholine by solid phase extraction at a 10μg sample range was favorable at σ=2.8. This method of separation was applied to determination of the fatty acid compositions of phospholipids in small amounts of plasma.

著者関連情報
© The Pharmaceutical Society of Japan
前の記事 次の記事
feedback