2019 年 83 巻 1 号 p. 56-66
Background: Identifying who among current Japanese patients with prior myocardial infarction (MI) would benefit from an implantable cardioverter-defibrillator (ICD) is imperative. Accordingly, this study seeks to determine whether single-photon emission computed tomography (SPECT) can help identify such patients.
Methods and Results: This retrospective study enrolled 60 consecutive patients with prior MI who underwent stress thallium-201 SPECT and ICD implantation from February 2000 to October 2014. Occurrence of arrhythmic death and/or or appropriate ICD therapy, defined as shock or antitachycardia pacing for ventricular fibrillation or tachycardia, was identified until November 2016. During the median follow-up interval of 6.6 years, 18 (30%) patients experienced arrhythmic death and/or appropriate ICD therapy. Multivariate Cox proportional hazard regression analysis revealed that the summed stress score (SSS) [hazard ratio (HR)=1.14; P=0.005] and left ventricular ejection fraction (LVEF) at rest (HR=0.92; P=0.038) were significantly associated with the occurrence of arrhythmic events. Patients with SSS ≥21 and LVEF ≤30%, which were determined to be the best cutoff points, had significantly higher incidence of the arrhythmic events than the other patients (64% vs. 11%; HR=7.18; log-rank P=0.001).
Conclusions: SSS using stress thallium-201 SPECT in combination with LVEF can help determine the need for ICD therapy among current Japanese patients with prior MI.