Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original papers
Chemical Interaction between Titanium Implant Surface and Amino Acids
Kyou HIASA, Yasuhiko ABE, Yasuhiro YOSHIDA, Tsuyoshi TAJI, Kazuomi SUZUKI, Yasumasa AKAGAWA
著者情報
ジャーナル フリー

2007 年 26 巻 2 号 p. 156-161

詳細
抄録
The purpose of this study was to investigate the chemical interaction between titanium implant surface and amino acids. Pure titanium disks were pretreated with 10 N HCl and ultrapure water at room temperature for 30 minutes each. Disks were then modified with one of the three amino acids—L-aspartic acid, L-serine, or L-threonine—at 37°C for 12 hours. Modification with oxalic acid was used as a control. By means of X-ray photoelectron spectroscopy (XPS), amino acid powders and the modified surfaces without or with ultrasonic water rinsing were chemically analyzed. It was revealed that the N 1s peak which originated from amino acids was not or hardly detected in the wide scan spectra of amino acid-modified surfaces. Moreover, the COO- peak which originated from oxalic acid could hardly be detected in the narrow scan spectrum of the C 1s region of oxalic acid-modified surface with ultrasonic water rinsing. Based on the results of this study, it was concluded that amino acids could not chemically bond to the titanium surface.
著者関連情報
© 2007 The Japanese Society for Dental Materials and Devices
前の記事 次の記事