IEICE Electronics Express
Online ISSN : 1349-2543
ISSN-L : 1349-2543
LETTER
High resolution LFMCW radar system using model-based beat frequency estimation in cable fault localization
Chun Ku LeeJin Bae ParkYong-June ShinTae Sung Yoon
著者情報
ジャーナル フリー

2014 年 11 巻 1 号 p. 20130768

詳細
抄録
A linear frequency modulated continuous wave (LFMCW) radar is introduced to localize the impedance discontinuities on the instrument cable used in nuclear plants. The LFMCW reflectometry uses a phenomenon that electromagnetic pulses are reflected at the impedance discontinuities to localize impedance discontinuity points on the cable. For localizing impedance discontinuities, time delays between the incident signal and the reflected signals from the impedance discontinuities have to be measured. The LFMCW is modeled by time-varying auto-regressive (AR) model. From the coefficients of the AR model, instantaneous frequency is estimated by the Kalman filtering to calculate the time delays. The performance of the proposed method is verified by experiments.
著者関連情報
© 2014 by The Institute of Electronics, Information and Communication Engineers
前の記事 次の記事
feedback
Top