A Power Factor Correction with Two-Input Current Mode using Voltage Doubler Rectifier
Isamu YamamotoKeiju Matsui
Author information
JOURNAL FREE ACCESS

2001 Volume 121 Issue 2 Pages 225-230

Details
Abstract
For small capacity rectifier circuits with a small capacity, such as those for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a voltage doubler rectifier without switching devices. In this method, the input current is divided into two periods, where the small input capacitor is charged during one period and the large output capacitor through large inductor is charged during the other. By dividing the input current into two different modes, the current conduction period can be widened and harmonics can largely be canceled between the two modes. Hence, the harmonic characteristics can be significantly improved, whereby the lower order harmonics, such as the fifth and seventh orders, are much reduced. The results are confirmed by theoretical and experimental implementations.