電気学会論文誌E(センサ・マイクロマシン部門誌)
Online ISSN : 1347-5525
Print ISSN : 1341-8939
ISSN-L : 1341-8939
特集論文
温度差センサのヒータ駆動切替えによる広範囲圧力測定
高嶋 徳明木村 光照
著者情報
ジャーナル フリー

2009 年 129 巻 12 号 p. 444-449

詳細
抄録
We have extended measurable pressure range of the thin film Pirani vacuum sensor that is still sensitive above 1×105 Pa (1 atmosphere). In our thin film Pirani vacuum sensor, our proposed temperature difference sensor of the short circuit Seebeck-current detection type thermocouple is used in order to get extremely high sensitivity, especially both in very low pressure range and in higher pressure range than 1×104 Pa. In our new pressure sensor the cantilever type sensing region, in which a microheater and two thermocouples are formed to measure the temperature difference, is adopted. Therefore, we can use the null method to measure very small pressure accurately in the high vacuum range (low pressure range). On the other hand in the higher pressure than 1×104 Pa., we could expand the pressure range by adoption of the vibration of the sensing cantilever based on the sudden heating due to the exchange of heater driving. We have achieved much wider measurable pressure range over 8 digits by use of our new simple thin film Pirani vacuum sensor than that of the traditional one.