日本原子力学会誌
Online ISSN : 2186-5256
Print ISSN : 0004-7120
ISSN-L : 0004-7120
遠心ポンプのヘッドおよびトルクの二相流定常特性実験
湊 明彦富永 研司
著者情報
ジャーナル フリー

1988 年 30 巻 3 号 p. 247-256

詳細
抄録
Circulation pump behavior has large effect on coolant discharge flow rate in case of reactor pipe break. Experiment of two-phase pump performance was conducted as a joint study of Japanese BWR user utilities and makers.
Two-phase head and torque of three centrifugal pumps in high temperature and high pressure (around 6 MPa) steam/water were measured. Head was decreased from single-phase characteristics when gas was mixed in liquid flow in condition with normal flow and normal rotation directions. When flow rate was large enough, two-phase head was about the same as single-phase one in reversal flow conditions. Two-phase head was smoothly increased as flowing steam volumetic concentration increased when flow rate was small and flow direction was reversal. Changes of torque with gas concentration were correspondent to those of head. This suggested that changes of interaction between flow and impellers due to phase slip effected on torque which caused head differences between single- and two-phase flows. Dependence of dimensionless head and torque of three test pumps on steam concentration were almost the same as each other.
著者関連情報
© by the Atomic Energy Society of Japan
前の記事 次の記事
feedback