衛生化学
Print ISSN : 0013-273X
Direct Detection of Glutathione S-Transferase on a Gel Plate by Treatment with Glutathione and 1-Chloro-2, 4-dinitrobenzene
HIDEO ISONOSHUICH MIYAURA
著者情報
ジャーナル フリー

1985 年 31 巻 6 号 p. 377-384

詳細
抄録
A method was developed to directly detect glutathione S-transferase (GST) on the surface of a gel-plate after electrophoresis. First, a photograph of the background photoabsorption of the gelplate was taken by exposing photographic paper laid under the gel-plate to ultraviolet light (365 nm) without any chemical treatment of the gel surface. Next, the same plate was evenly coated with a solution consisting of 3 ml of 20 mM reduced glutathione (GSH) in water and 0.3 ml of 30 mM 1-chloro-2, 4-dinitrobenzene (CDNB) in ethanol. This plate was observed under ultraviolet light (365 nm), and photoabsorbing spots were directly photographed by the same method as before. Finally, the same plate was stained with Coomassie Brilliant Blue R-250 to give a protein picture. The mutual comparison of these three electrophoretic pictures made it possible to detect GSTs despite the presence of many other proteins on the gel-plate.
著者関連情報
© The Pharmaceutical Society of Japan