逆Stenvers氏撮影法の有用性の検討
丸山 裕稔井手口 忠光大浦 弘樹東 敏也折田 信一天野 一弘東田 善治
著者情報
ジャーナル フリー

2003 年 59 巻 7 号 p. 872-878

詳細
抄録

In otorthinolaryngology, Stenvers' method is employed in radiography of the pyramid (internal acoustic meatus and semicircular canals). However, in cases of dizziness, where the prone position is difficult to achieve, we occasionally use the opposite Stenvers' method instead of the conventional one. This makes it possible to perform radiography with the patient in the supine position. Compared with the conventional Stenvers' method, the problems of this method were increases not only in the rate of magnification but also in lens dose. In this study, we evaluated these problems by employing computed tomography (CT) and a glass dosimeter with phantom as well as by clinical evaluation. The results showed no statistically significant difference between Stenvers' method and the opposite Stenvers' method in both the rate of magnification and the clinical evaluation. The increase in lens dose with the opposite Stenvers' method was not significant. We concluded that the opposite Stenvers' method was useful.

著者関連情報
© 2003 公益社団法人 日本放射線技術学会