体幹部領域における深吸気時停止SPECT法の有用性に関する研究 : 分解能の向上に関する検討
河合 崇史堀内 承治林 万寿夫杉林 慶一二沢 佳史本村 信篤出口 千尋芦田 健次高山 正弘重 忠行福西 康修寺川 彰一
著者情報
ジャーナル フリー

2005 年 61 巻 8 号 p. 1144-1150

詳細
抄録

Because SPECT images are acquired under normal respiration, the respiratory motion induces artifacts and decreases resolution. In this study we developed a novel method of acquiring SPECT data during deep inhalation breath-hold (BrST) and assessed its efficacy in reducing motion artifacts and improving resolution. Reproducibility studies found that variations in SPECT image homogeneity were reduced using the BrST method to within a clinically non-problematic range. An experiment using a custom-built respiration phantom showed almost complete elimination of motion artifacts and significant improvement in resolution using the BrST method. Clinical assessment confirmed a significant reduction in motion artifacts along with the improvement in resolution. The BrST method enabled visualization of lesions that previously had been impossible to detect by standard acquisition under normal respiration. The BrST method is expected to both significantly reduce motion artifacts and improve resolution.

著者関連情報
© 2005 公益社団法人 日本放射線技術学会