日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
ノート
放射線治療部門におけるスタッフ・新人技師による患者Setup Errorの統計学的有意差解析
山口 紘子松本 光弘太田 誠一植田 崇彦筒井 保裕
著者情報
ジャーナル フリー

2012 年 68 巻 5 号 p. 602-607

詳細
抄録

Introduction: We verified the setup error (SE) in two persons’ radiation therapist’s team, which consist of staff and new face. We performed the significance test for SE by the staff group and the new face group. Methods: One group consists of four staff therapists with at least 5 to 30 years of experience. The other group consists of new face radiation therapists that have 1 to 1.5 years of experience. Analyzed were 53 patients diagnosed with pelvic cancer (seven patients who underwent 3 dimensional conformal radiation therapy (3DCRT) and 46 patients who underwent intensity modulated radiation therapy (IMRT). Image verification was 1460 times. It was performed through setup verification by cone beam computed tomography (CBCT), and we measured SE of four directions (lateral, long, vertical, 3D). We performed the student’s t-test to get the difference of the average error between the staff group and the new face group. Results: The results of significance tests show that there is no difference between SE in the staff group and the new face group in radiotherapy.

著者関連情報
© 2012 公益社団法人 日本放射線技術学会
前の記事 次の記事
feedback
Top