日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
臨床技術
急性期脳梗塞 CT検査における逐次近似応用再構成法の有用性
多田 佳司内田 幸司金山 秀和梶谷 尊郁山本 泰司真田 茂
著者情報
ジャーナル フリー

2015 年 71 巻 11 号 p. 1090-1095

詳細
抄録
We evaluated clinical images to investigate the usefulness of adaptive iterative dose reduction algorithm (AIDR) in the field of acute cerebral infarction. We did receiver operating characteristic (ROC) analysis by 4 radiologists using 50 clinical images (abnormal case=24, normal case=26) which were reconstructed by AIDR and filtered back projection (FBP). The area under the curve (AUC) value from average ROC curve of observers were 0.79 with the FBP and 0.87 with the AIDR (P=0.31). The standard deviation of AUC was 0.06 with the FBP and 0.03 with the AIDR. More in detail, the AUC value of Expert group (over 10 years of experience) increased to 0.06 by using AIDR compared with FBP method. On the other hand, in Beginner group (less than 10 years of experience) there was 0.09 increase. Therefore, there was some possibility to reduce the variation of diagnostic accuracy among observer and the diagnostic accuracy improvement of the doctor in a few Experience group, by using AIDR for acute cerebral infarction computed tomography (CT) examination.
著者関連情報
© 2015 公益社団法人 日本放射線技術学会
前の記事 次の記事