日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
臨床技術
ワークステーション搭載型ノイズ低減処理ソフトが MR 画像の画質に与える効果
山室 修築島 正拓
著者情報
ジャーナル フリー

2021 年 77 巻 12 号 p. 1416-1423

詳細
抄録

In magnetic resonance imaging (MRI) examinations, a trade-off is noted among acquisition time, resolution, and signal-to-noise ratio (SNR). High-resolution images are expected to improve the detection of small lesions. However, to ensure a high SNR, the imaging time must be extended. If the number of additions is reduced to shorten the imaging time, a reduction in slice thickness and in-plane resolution is necessary to ensure an adequate SNR. A combination of acceleration and denoising using deep learning has been previously reported. However, although it may be useful as a noise reduction technique onboard device, it cannot be used for general purposes. We studied the effects of a recently developed general-purpose image-based noise reduction software on MRI by measuring SNR and other parameters such as contrast, resolution, and noise power spectrum (NPS). NPS was influenced by the difference in processing mode, whereas contrast remained uninfluenced. Regarding resolution, the edge information was retained and was found to be better in iNoir 3D than in iNoir 2D. However, owing to the increased intensity of noise-reduction processing, the slope of the edge in the low-contrast area was smoothed, presenting a visually blurred impression.

著者関連情報
© 2021 公益社団法人 日本放射線技術学会
前の記事 次の記事
feedback