動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: D216
会議情報

清掃工場におけるエネルギー利用の実態調査
尾上 真輝稲積 えり西村 伸也上殿 紀夫
著者情報
会議録・要旨集 フリー

詳細
抄録

In the big cities, a large amount of garbage has been incinerated in the incineration plant. In the large-scale plant, steam power cycle using incineration exhaust heat to the heat source has been introduced. In this steam cycle, unlike the commercial thermal power generation system, the condensation of the vapor is carried out using an air-cooled condenser, influenced by the outdoor temperature. Therefore, in the high temperature summer season, the power generation amount is decreased and also a higher temperature waste heat is released to the atmosphere. Therefore, in this study, in a large-scale incineration plant in Osaka City, the actual situation of energy use was investigated twice in the summer and winter. Specifically, seasonal changes in the amount of power generation as well as the condenser exhaust gas temperature were investigated. Moreover, based on the measurement result, some points of performance improvement were revealed by the exergy analysis.

著者関連情報
© 2016 一般社団法人 日本機械学会