ロボティクス・メカトロニクス講演会講演概要集
Online ISSN : 2424-3124
セッションID: 2P1-19b2
会議情報

集積型マイクロバキュームチャックシステムを用いた3次元組織の機械的特性測定
上杉 薫福本 健島 史明明石 満森島 圭祐
著者情報
会議録・要旨集 フリー

詳細
抄録

The mechanical properties are indispensable parameter for evaluate the 3 dimensional tissues. In this report, we developed an integrated micro vacuum chuck (IMVC) which could fix the three-dimensional multilayered tissue to tensile test system without stress concentrations and tensile test system for IMVC. Newly developed system can adjust vacuum pressure because IMVC was connected to vacuum pump and pressure sensor directory. The three-dimensional multilayered tissues were fabricated with technique of layer-by-layer (LbL) nanofilm coatings. By using the IMVC, we succeeded to measure tensile force of the three-dimensional multilayered tissues without stress concentrations. In the result, the maximum tensile force was about 410 μN (strain: 0.6). When strain reached 0.5, we measured tensile force about 350 μN and this value was same order of conventional study. Therefore, it was considered that the IMVC was useful tool for fixing 3D tissues in measurement of mechanical properties of 3D tissue.

著者関連情報
© 2016 一般社団法人 日本機械学会