精密工学会誌論文集
Online ISSN : 1881-8722
Print ISSN : 1348-8724
ISSN-L : 1348-8716
論文
グランドパッキン側圧測定法の研究
廣田 輝直内藤 正博松波 豪和田 将典保坂 寛
著者情報
ジャーナル フリー

2006 年 72 巻 10 号 p. 1301-1306

詳細
抄録
For the users of automatic control valves, leakage of the fluid from the gland packing portion has been a problem as main cause of failure. In this research, the measuring method of the radial pressure of the gland packing, which is directly related to the sealing characteristics, is proposed. The semiconductor pressure transducer is attached to the bonnet, and through the grease filled in the hole in the bonnet, the radial pressure was directly measured. First, the validity of the proposed method was confirmed by comparison of the result to the pressure value expected from the strain of the bonnet. Next, this measuring method was applied to the model system. The radial pressure distribution of the piled packing and its dynamic behavior under conditions the stem was driven was successfully observed. Consequently, the method was shown to be useful to observe the radial pressure distribution, especially in dynamic conditions.
著者関連情報
© 2006 公益社団法人 精密工学会
前の記事
feedback
Top