日本建築学会計画系論文集
Online ISSN : 1881-8161
Print ISSN : 1340-4210
ISSN-L : 1340-4210
温度成層流中のストリートキャニオン内の濃度分布に関する風洞実験 : 市街地における汚染物の拡散に関する実験的研究 その3
上原 清村上 周三老川 進若松 伸司
著者情報
ジャーナル フリー

1997 年 62 巻 499 号 p. 9-16

詳細
抄録
Results of wind tunnel experiments on the concentration fields within urban street canyons are presented. The concentrations within such canyons are highly dependent on stability conditions. Even in a street, parallel to the wind direction, reverse flow seems to occur except under very stable stratified conditions. The mean concentration within the street canyon can be estimated from the pollutant exhaust flux, the flow rate of the cavity eddy and the recirculation ratio of pollutant. Concentrations estimated from the SRI street canyon model are roughly in agreement with wind tunnel results and the coefficients used in the model can be estimated from measurements of the flow field in the canyon.
著者関連情報
© 1997 日本建築学会
前の記事 次の記事
feedback
Top