抄録
This paper presents the characteristics of the pedestrian movement around the door connected to a corridor. We focused on the flow rate where a door connects to a corridor to verify evacuation safety, based on performance-based design. Full-scale evacuation experiments were conducted to confirm that a decrease in flow rate would occur when passing through an opening. A flow rate of 1.5 persons/m/s is assumed as the convention for Japanese Building-Standard Law. However, when the corridor connected to the door is crowded, flow rate at the door decreases. Therefore, the effective flow rate, which changes in relation to the effective area of corridor available, was used in Japanese performance-based codes to accurately evaluate the evacuation time of buildings in a fire. Furthermore, the differences between this experiment and “SimTread” (a multi-agent pedestrian simulator) were investigated to examine the validity of the simulation.