日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
常時微動計測による木造建物の最大変形推定手法の精度検証
西塔 純人杉野 未奈林 康裕
著者情報
ジャーナル フリー

2020 年 26 巻 64 号 p. 929-933

詳細
抄録

At the past paper, the relationship of natural frequency of microtremor measurement and maximum experienced deformation angle about low-rise houses was proposed. In this paper, it was conducted the accuracy verification of the aforementioned relationship, using the full scaled shaking table tests and the post-earthquake investigation, about Japanese conventional wooden structure and Japanese traditional wooden one. And, through investigation before and after the earthquake of a Japanese conventional wooden house, the effectiveness of the proposed relationship was confirmed.

著者関連情報
© 2020, 日本建築学会
前の記事 次の記事
feedback