Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Notes
Determination of Oxycodone and Hydrocotarnine in Cancer Patient Serum by High-Performance Liquid Chromatography with Electrochemical Detection
Hideya KOKUBUNMakiko OUKIMotohiro MATOBAHiroaki KUBOSumio HOKAKazuo YAGO
著者情報
ジャーナル フリー

2005 年 21 巻 3 号 p. 337-339

詳細
抄録
We developed an HPLC procedure using electrochemical detection for the quantitation of oxycodone and hydrocotarnine in cancer patients serum. An eluent of methanol:acetonitrile:5 mM pH 8 phosphate buffer (2:1:7) was used for the mobile phase. The calibration curve was linear in the range from 10 ng/mL to 100 ng/mL. The recovery of oxycodone and hydrocotarnine was 97.2% and 90.5%, respectively. The relative standard deviations within-runs and between-runs for the assay of oxycodone or hydrocotarnine were less than 4.8%. The method developed here was better than the method reported previously.
著者関連情報
© 2005 by The Japan Society for Analytical Chemistry
前の記事 次の記事
feedback
Top