Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843
Case Report
First Case Report in Japan of Left Ventricular Pacing via a Coronary Vein in a Patient With a Mechanical Tricuspid Valve
Masataka YodaToshiko NakaiKimie OkuboMitsumasa HataAkira SezaiAtsushi HirayamaKazutomo Minami
著者情報
キーワード: Arrhythmia, Pacemaker, Valves
ジャーナル フリー

2008 年 72 巻 2 号 p. 335-336

詳細
抄録
Transvenous endocardial pacemaker implantation is contraindicated in patients after prosthetic tricuspid valve replacement. A 65-year-old woman underwent both replacement of the mitral and tricuspid valves and pacemaker implantation with epicardial lead for bradycardia with chronic atrial fibrillation. At 2 years after this operation, the pacemaker's battery became low, and she was admitted for a battery exchange. To avoid frequent battery exchanges because of high stimulation thresholds, a left ventricular pacing lead was implanted via a coronary vein. There were no complications and the stimulation thresholds were stable. Coronary vein leads enable a minimally invasive approach, improve safety, and give effective stimulation for patients with a prosthetic tricuspid valve. This is the first case report in Japan of left ventricular pacing in such a patient. (Circ J 2008; 72: 335 - 336)
著者関連情報
© 2008 THE JAPANESE CIRCULATION SOCIETY