Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Setting and Flexural Properties of Metal-Resin Composite Using Ag-Cu Particles as Filler and Chemical Accelerator
Hiroko SOMAYukio MIYAGAWAHideo OGURA
著者情報
キーワード: Dental composite, Ag-Cu alloy, 4-META
ジャーナル フリー

2003 年 22 巻 4 号 p. 543-555

詳細
抄録

A metal-resin composite material was experimentally prepared by mixing a powder consisting of Ag-Cu particles and BPO with a paste consisting of UDMA-based monomer and 4-META in the absence of tertiary amine. The working time and setting time were mainly affected by the amounts of 4-META, BPO and metal particles, most of them fulfilling the requirements for working time and setting time specified in ISO4049: 2000 in the present experimental conditions. The flexural strength ranged from 49.6MPa to 77.8MPa, and the highest value was obtained when the 4-META concentration was high and metal particle content was low. The flexural modulus of elasticity, ranging from 6.7GPa to 11.9GPa, significantly increased as the 4-META concentration and metal particle content increased. Based on its mechanical properties, this metal-resin composite in which metal particles are involved in the polymerization initiation system has the potential to be used as a dental restorative material.

著者関連情報
© The Japanese Society for Dental Materials and Devices
前の記事 次の記事
feedback
Top