衛生化学
Print ISSN : 0013-273X
大気汚染度測定法に関する研究I : 活性炭塗布ろ紙法によるイオウ酸化物の測定
池田 坦
著者情報
ジャーナル フリー

1967 年 13 巻 1 号 p. 41-45

詳細
抄録
The application of the active carbon filter paper method for detection of sulfur oxide in air was studied. Active carbon powder was mixed with tragacanth gum solution, and the mixture was plastered on Toyo filter paper No. 26 in 100 cm2. It was found that the result of measurement by this method was inferior to filter paper method. But the addition of sodium acetate to the active carbon powder improved this method and good results were obtained.
著者関連情報
© 社団法人 日本薬学会
前の記事 次の記事
feedback
Top