衛生化学
Print ISSN : 0013-273X
ベンゾジアゼピン系薬物のサーモスプレイLC/MS及び大気圧化学イオン化LC/MSによる分析
辰野 道昭西川 眞弓土橋 均五十嵐 一雄糟谷 史代福井 巳芳
著者情報
ジャーナル フリー

1996 年 42 巻 3 号 p. 248-256

詳細
抄録
To assess the LC/MS methods for the determination of these compounds in biological materials positive ion mass spectra were measured for benzodiazepines and their metabolites by thermospray-liquid chromatography/mass spectrometry (TSP-LC/MS) and atomospheric pressure chemical ionization-liquid chromatography/mass spectrometry (APCI-LC/MS). In both TSP-LC/MS and APCI-LC/MS, LC analyses were performed on a TSKgel octyl-80Ts in the solvent system of methanol-ammonium acetate at a flow rate of 1.0 ml/min. TSP mass spectra showed only a [M+H]+ ion for most of compounds, while APCI mass spectra showed [M+H]+ and some fragment ions. The analysis of these compounds with TSP gave better detection limits than with APCI by scan mode, and gave the same results for detection limits as with APCI by selected ion monitoring (SIM). The data, described in this paper, should serve as a basis for the qualitative and quantitative analyses of benzodiazepines and their metabolites in biological samples.
著者関連情報
© 社団法人 日本薬学会
前の記事 次の記事
feedback
Top