Simple Solution for Preventing Cerebrospinal Fluid Loss and Brain Shift During Multitrack Deep Brain Stimulation Surgery in the Semisupine Position: Polyethylene Glycol Hydrogel Dural Sealant Capping
—Rapid Communication—
Ichiro TAKUMIMasahiro MISHINAKohei HIRONAKAKenichi OYAMAAkira YAMADAKoji ADACHIMakoto HAMAMOTOShin KITAMURADaizo YOSHIDAAkira TERAMOTO
著者情報
ジャーナル オープンアクセス

2013 年 53 巻 1 号 p. 1-6

詳細
抄録
This study evaluated preliminary findings on the efficacy of polyethylene glycol (PEG) hydrogel dural sealant capping for the prevention of cerebrospinal fluid (CSF) leakage and pneumocephalus during deep brain stimulation (DBS) surgery in the semisupine position. Group A consisted of 5 patients who underwent bilateral subthalamic nucleus (STN)-DBS surgery without PEG hydrogel dural sealant capping. Group B consisted of 5 patients who underwent bilateral STN-DBS surgery with PEG hydrogel dural sealant capping. The immediate postoperative intracranial air volume was measured in all patients and compared between the 2 groups using the Welch test. Adverse effects were also examined in both groups. The intracranial air volume in Group A was 32.3 ± 12.3 ml (range 19.1-42.5 ml), whereas that in Group B was 1.3 ± 1.5 ml (range 0.0-3.5 ml), showing a significant difference (p < 0.005). No hemorrhage or venous air embolisms were observed in either group. The effect of brain shift was discriminated by STN recordings in Group B. These preliminary findings indicate that PEG hydrogel dural sealant capping may reduce adverse effects related to CSF leakage and brain shift during DBS surgery.
著者関連情報
© 2013 by The Japan Neurosurgical Society

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/