日本水産学会誌
Online ISSN : 1349-998X
Print ISSN : 0021-5392
ISSN-L : 0021-5392
赤沼式比重計の比重測定精度に關する實験(第一報)
宇田 道隆山下 利得
著者情報
ジャーナル フリー

1939 年 8 巻 4 号 p. 173-177

詳細
抄録
Sources of errors attached to the pycnometry of sea water such as the variation of surface tension aroused by the varied condition of the glass surface of the hydrometer, by the contamination of water surface due to dust, oil etc. or by the convection in the water specimen, also with personal error, which are superposed in complexed manner, were investigated carefully. As the result of statistics and the experiments on the effects of the contamination of water surface etc. it was shown that the accuracy of the density measurement by means of the Akanuma's Hydrometer is usually of the order of 0.1‰ S.
著者関連情報
© 社団法人 日本水産学会